Embedded UPS for Mikrotik CCR2004-1G-12S+2XS
Backup power from an external battery 12 V

How does it work?
The UPS EF6012 powers the router and charges the battery simultaneously, and in the absence of AC 220 V, it switches to the battery power. The reserve time depends on the capacity, for example a 12 V 20 Ah battery will provide more than 3 hours of reserve power for the CCR2004-1G-12S+2XS.

Is it safe?
In telecom equipment with 12 V power, voltage controllers on the board have an input range from 10 V to 15 V, electrolytes are set to 16 V, while the output voltage of the UPS when a battery is charged has up to 13.8 V, which is within the permissible limits. We use high-quality components, on the level with the original power supplies: Nippon Chemi-Con, Texas Instruments, Diodes, Infineon Technologies, Sharp, etc. Uninterruptible power supplies EF6012 are designed specifically for installation in switches, routers and OLTs. Since 2015 they have been working with hundreds of models of equipment from different manufacturers (Alcatel, BDCOM, Cisco, C-Data, D-Link, Dell, DCN, Edge-Core, Foxgate, Huawei, HP, Linksys, Planet, Raisecom, TM STELS, Zyxel).
What are the advantages of an embedded UPS?
- Backup power from an external battery 12 V (7 Ah ~ 1 hour ... 100 Ah ~ 20 hours for CCR2004-1G-12S+2XS).
- Saving space by installing the UPS inside the equipment.
- Charge in CC/CV mode, protection against deep discharge or overcharge the battery.
- Efficiency up to 98 % due to the absence of double conversion (12 V →
220 V→ 12 V) when working from a battery. Accordingly, the reserve time is longer.

What is required to install a UPS?
No need to drill or cut anything. We took care of everything.
List of components:
- UPS EF6012 - 1 pc;
- Cable for battery with F2 terminals (BAT-CAB-1M-T6) or bolt M6 terminals (BAT-CAB-1M-D6) - 1 pc;
- Адаптер ADAPT-NX4-MF4-WHITE - 1 pc;
- Socket 220 V with a cutout for the battery cable (ADAPT-AC-MIKROTIK) - 1 pc;
- Battery 12 V - 1 pc.
Screwdriver and 20 minutes of free time.

Installation sequence:
- Unscrew the bolts, remove the cover and take out the native power supply.
- EF6012 fits perfectly, replacing stock power supply: mounting holes and jacks match.
- Connect the adapter and the battery cable to the appropriate connectors.
- Carefully remove the 220 V connector and replace it with ours (with a cutout for the battery cable outlet).
Important! - before installing a new connector is required to lead the battery cable out through the hole, and then insert the connector itself.
If necessary, the original power supply and connector can be put back in place.

What other MikroTik models does this UPS fit?
- CRS312-4C+8XG-RM
- CCR1036-12G-4S
- CCR1036-12G-4S-EM